| Code | Parameter Name | Description | Typical Range | Recommended Setting | | :--- | :--- | :--- | :--- | :--- | | | Setpoint | Desired controlled temperature | LS to US | 2.0°C (cooler) / -18.0°C (freezer) | | Hy | Hysteresis | Differential (cut-in – cut-out). Compressor starts at SP+Hy, stops at SP. | 0.1 to 25.0°C | 2.0°C (reduces cycling) | | LS | Minimum Setpoint | Lower limit to lock SP | -50 to US | -30°C (freezer) / 0°C (cooler) | | US | Maximum Setpoint | Upper limit to lock SP | LS to 150°C | 8.0°C (cooler) / 0°C (freezer) | | OdO | On Delay Output | Delay before energizing output after power-up | 0 to 250 min | 2 min (protects compressor) | | dLy | Delay | Minimum off time for compressor | 0 to 60 min | 5 min (crucial for compressor life) | | PA | Password | Access code for parameter menu | 0 to 199 | 3 (default) | | C_F | Temperature Scale | Celsius or Fahrenheit | C / F | C (or F for USA) | | S1P | Probe 1 Type | Type of temperature probe | PtC / ntC | ntC (usually for NTC 10k) or PtC |

This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later. eliwell sb655 c manual

Use flexible copper wires with a cross-section of 0.5 mm² to 2.5 mm² (AWG 20 to AWG 14) for power supply and relay connections.

: Optimized for units without a storage battery/tank.

Cause: The cabinet temperature has exceeded SEt + HAL for longer than the tAO time delay. Eliwell lags behind in user-friendliness

Do you need assistance mapping out a specific or calculating defrost schedules for your system? Share public link

Installing and configuring the Eliwell SB655 C requires careful attention to detail to ensure optimal performance. The manual provides step-by-step instructions for:

Offers automatic summer/winter operation switching and "Free Cooling" or "Free Heating" modes to optimize energy efficiency. Can’t copy the link right now

| Display | Cause | Action | |---------|-------|--------| | | Probe error (open/short) | Check probe/wiring. Replace if needed. | | HA | High temperature alarm (>AH) | Check cooling system, door closure. | | LA | Low temperature alarm (<AL) | Check setpoint, evaporator fan. | | EA | External alarm (digital input) | Check external device (door, pressure switch). | | dF | Defrost timeout (temp not reached) | Increase dE or check heater. |

Press , enter the password (default is usually 15 or 22 ), and press Set . Use the arrow keys to scroll through the parameters. Critical Parameter Reference Table Description Typical Range Standard Default diF Temperature Differential (Hysteresis) 0.1°C to 30.0°C HSE Maximum Setpoint Limit Setpoint to 99°C LSE Minimum Setpoint Limit -55°C to Setpoint dty Defrost Type (0 = Electrical, 1 = Hot Gas, 2 = Off) dit Interval Between Defrost Cycles 0 to 120 hours dEt Maximum Defrost Duration 1 to 250 minutes 30 minutes FSt Fan Stop Temperature -50°C to 120°C Ont Compressor On Time during probe failure 0 to 250 minutes 15 minutes Defrost Management

These control how the compressor behaves.